Early Intervention (Whole Body Vibration) to Reduce Bone Loss After Spinal Cord Injury
Spinal Cord Injury · Osteoporosis
Enrolment: 60 · Results not recorded
Device · Device/physical therapy (whole-body vibration); not a ChEMBL entity
1 linked trials carry an injury-indication flag. These flags support record-level exploration and sit alongside the stringent aggregate counts described in Methods.
Spinal Cord Injury · Osteoporosis
Enrolment: 60 · Results not recorded
Duchenne Muscular Dystrophy
Enrolment: 4 · Results not recorded
1 studies reported at therapy level; 1 evidence entries itemised.
Model: Complete surgical transection of the left medial collateral ligament at the midsubstance, with immediate weightbearing allowed
Vibration did not change ultimate tensile load (injured p = 0.925) or structural stiffness (p = 0.542) of the transected ligament, nor histological appearance. In the intact Achilles tendon of the injured limb, vibration increased collagen 1 alpha 3-fold, interleukin 6 7-fold, cyclooxygenase-2 5-fo…
Extraction: extract · Supplied extraction confidence: 0.9. Machine-extracted fields require source verification.