Porous titanium implants improve tendon healing in an acute rat supraspinatus repair model.

Rat / Other

Evidence by therapy association

Study details and outcomes are extracted in the context of a specific intervention. Separate associations are retained rather than silently merged.

PMID 27751717 ↗2016Reported benefit

Porous titanium implants improve tendon healing in an acute rat supraspinatus repair model.

RatOtherSprague-Dawleymalen = n=40 rats total, time 0 n=3, 2 weeks n=8, 4 weeks n=15, 12…surgical implantation at the tendon-to-bone interfaceplaced at the time of surgical repair

Model: acute surgical supraspinatus tendon repair, rotator cuff repair model with implant at the tendon-to-bone interface, contralateral shoulder design

Porous titanium implants improved early biomechanical properties of tendon-to-bone healing versus standard repair, with increased elastic modulus, maximum load and maximum stress at 2 and 4 weeks and decreased cross-sectional area at 4 weeks, with no foreign body reaction and viable bone within the…